Provides closure for the branch of the trunk of the tee.
|
Provides closure for the branch of the trunk of the tee.
|
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall.
|
|
|
|
|
|
|
|
|
|
|
|
|
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall.
|
Use as a counter flashing. Use mastic to seal the vent pipe.
|
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall.
|
|
|
|
|
|
|
|
|
|
|
|
|
Connects Type B gas vent directly to an appliance draft hood. The flexible inlet can be shaped to fit oval draft hood outlets.
|
Connects Type B gas vent directly to an appliance draft hood. The flexible inlet can be shaped to fit oval draft hood outlets.
|
Provides a cover for rough wall openings and serves as a firestop.
|
|
|
|
|
|
|
|
|
|
|
|
|
Provides a cover for rough wall openings and serves as a firestop.
|
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall.
|
The firestop support supports Type B gas vent starting at the appliance level and includes a support bracket. The support bracket (SB) and firestop (FS) are also available separately. Supports up to 20 ft.
|
|
|
|
|
|
|
|
|
|
|
|
|
The increaser is used to increase vent size. A max of 4 step of increase.
|
The increaser is used to increase vent size. A max of 4 step of increase.
|
The firestop support supports Type B gas vent starting at the appliance level and includes a support bracket. The support bracket (SB) and firestop (FS) are also available separately. Supports up to 20 ft.
|
|
|
|
|
|
|
|
|
|
|
|
|
Connects Type B gas vent directly to an appliance draft hood. The flexible inlet can be shaped to fit oval draft hood outlets.
|
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall.
|
The firestop support supports Type B gas vent starting at the appliance level and includes a support bracket. The support bracket (SB) and firestop (FS) are also available separately. Supports up to 20 ft.
|
|
|
|
|
|
|
|
|
|
|
|
|
The increaser is used to increase vent size. A max of 4 step of increase.
|
The increaser is used to increase vent size. A max of 4 step of increase.
|
The increaser is used to increase vent size. A max of 4 step of increase.
|
|
|
|
|
|
|
|
|
|
|
|
|
The standard flashing fits flat to 5/12 pitch roof and is made of double-seamed construction for protection from leakage. For a standard flashing with a 6 in skirt, the model number reads the size and EFFU or RFFU.
|
The standard flashing fits flat to 5/12 pitch roof and is made of double-seamed construction for protection from leakage. For a standard flashing with a 6 in skirt, the model number reads the size and EFFU or RFFU.
|
The AmeriVent cap is the first engineered vent cap to gain recognition across the country for its performance. Millions of them are now installed on homes and business structures to protect against wind conditions that can cause waste gases to spill back into the structure through the appliance draft hood. The AmeriVent cap is UL listed and its patented design of ports and baffles keep rain and debris out of the vent. In addition, AmeriVent caps permit termination of vents at the minimum height necessary above the roof surface. The AmeriVent cap is used as a ventilation cap as well as a Type B gas vent termination.
|
|
|
|
|
|
|
|
|
|
|
|
|
The AmeriVent cap is the first engineered vent cap to gain recognition across the country for its performance. Millions of them are now installed on homes and business structures to protect against wind conditions that can cause waste gases to spill back into the structure through the appliance draft hood. The AmeriVent cap is UL listed and its patented design of ports and baffles keep rain and debris out of the vent. In addition, AmeriVent caps permit termination of vents at the minimum height necessary above the roof surface. The AmeriVent cap is used as a ventilation cap as well as a Type B gas vent termination.
|
Used to common vent two or more appliances and provides better gas flow than a standard tee. The reduction wye features a branch and/or base with a smaller diameter than the trunk size.
|
Used to common vent two or more appliances and provides better gas flow than a standard tee. The reduction wye features a branch and/or base with a smaller diameter than the trunk size.
|
|
|
|
|
|
|
|
|
|
|
Used to common vent two or more appliances and provides better gas flow than a standard tee. The reduction wye features a branch and/or base with a smaller diameter than the trunk size.
|
The adjustable 90 deg elbow is constructed of four sections for smoother bends and less resistance. The elbow adjusts from 0 to 90 deg easily in order to clear rafters or ceiling joists.
|
|