Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL FITTINGS > METAL CONDUIT FITTINGS
Sort By:
1 2 3 ... 8
Halex 90440 Screw-In Connector Halex 90451 Screw-In Coupling Halex 96193 Rigid Conduit Locknut
Zinc die-cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2 in knock outs. Zinc die-cast. Use to join two pieces of flexible metallic conduit (Greenfield) together. Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure.
Halex 97525 Insulated Conduit Bushing Halex 91321 Reducing Conduit Bushing Halex 96194 Rigid IMC Conduit Locknut
High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL listed and CSA approved. Zinc die-cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL listed. Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure.
Halex 90481 Concrete Tight Set Screw Connector Halex 96195 Rigid Conduit Locknut Halex 91641 Box Spacer
Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. UL listed. Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure. Die cast of high strength corrosion-resistant zinc alloy. Locknut is reversible. It is designed to cut through protective coatings on boxes and enclosures to assure ground continuity. Use as a raceway between two steel outlet boxes or other metal enclosures. UL and CSA listed.
Halex 91530 Combination Coupling Halex 91332 Reducing Conduit Bushing Halex 91100 Conduit Elbow
Zinc die-cast. Use to join EMT conduit to non-metallic sheathed cable. #14/2, #12/3 or 2 #14/2. Indoor use only. UL approved. Zinc die-cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL listed. Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 90702 Conduit Chase Nipple Halex 12110 Concrete Tight Set Screw Connector Halex 97526 Insulated Conduit Bushing
Zinc die-cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. UL and CSA approved. Zinc die-cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL approved. High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL listed and CSA approved.
Halex 64005 Conduit Coupling Halex 75403 Anti-Short Conduit Bushing Halex 91331 Reducing Conduit Bushing
Steel, indoor or out. Use to join threaded Rigid or IMC conduit together. UL listed. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL approved. No 75400 fits cable range of 14/2, 14/3, 12/2 No 75401 fits cable range of 14/4, 12/3, 6/1, 4/1. No 75402 fits cable range of 12/4, 10/2, 10/3, 2/1. No 75403 fits cable range of 10/4, 8/2, 8/3, 1/1. No 75404 fits cable range of 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. Zinc die-cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL listed.
Halex 26071 Knock Out Seals Halex 91531 Combination Coupling Halex 75225 Insulated Conduit Bushing
Use to cover exposed knock-out holes in steel outlet boxes and other metal enclosures. Zinc die-cast. Use to join EMT conduit to flexible metal conduit. Indoor use only. With UPC. UL listed. High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL listed and CSA approved.
Halex 91101 Conduit Elbow Halex 90371 Concrete Tight Set Screw Conduit Offset Halex 90513 Twin Screw Clamp Connector
Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. Zinc die-cast. Use to connect EMT conduit to a metal outlet box or enclosure where an offset is desired. UL approved. Halex Clamp Connector, 1 in Trade, Zinc, 1-29/32 in Length, 1-1/8 in Width, 1-11/16 in Height, Suitable for: #14/2 to #6/3 AWG or #3/10/3 AWG Non-Metallic Cable or 0.45 to 0.73 in Dia Flex Cord
Halex 96196 Rigid IMC Conduit Locknut Halex 96401 Conduit Coupling Halex 75400 Anti-Short Conduit Bushing
Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure. Steel, indoor or out. Use to join threaded Rigid or IMC conduit together. UL listed. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL approved. No 75400 fits cable range of 14/2, 14/3, 12/2 No 75401 fits cable range of 14/4, 12/3, 6/1, 4/1. No 75402 fits cable range of 12/4, 10/2, 10/3, 2/1. No 75403 fits cable range of 10/4, 8/2, 8/3, 1/1. No 75404 fits cable range of 8/4, 6/2, 6/3, 4/2, 4/3, 6/4.
Halex 90401 Offset Nipple Halex 90452 Screw-In Coupling Halex 96402 Conduit Coupling
Zinc die-cast. Use as an offset connector between two enclosures. Offsets the axis of the raceway 3/4 in. UL approved. Zinc die-cast. Use to join two pieces of flexible metallic conduit (Greenfield) together. Steel, indoor or out. Use to join threaded Rigid or IMC conduit together. UL listed.
   
 
1 2 3 ... 8